Compliance with standards and directives
Directive conformity
EMC Directive 2004/108/EC EN 60947-5-2:2007+A1:2012
Standard conformity
Black/White difference (6 %/90 %) < 5 % at 150 mm
Diameter of the light spot approx. 10 mm at a distance of 150 mm
Angle of divergence approx. 4 °
Functional safety related parameters
MTTFd 600 a
Mission Time (TM) 20 a
Diagnostic Coverage (DC) 0 %
Indicators/operating means
Switching type The default setting is:
C/Q - BK: NPN normally open, PNP normally closed, IO-Link
Q2 - WH: NPN normally open, PNP normally closed
Signal output 2 push-pull (4 in 1)outputs,
short-circuit protected, reverse polarity protected, overvoltage protected
Usage category DC-12 and DC-13
IEC 60947-5-2:2007 + A1:2012
Mechanical specifications
Deree of protection IP67 / IP69 / IP69K
Connection 2 m fixed cable
Material
Housing PC (Polycarbonate)
Optical face PMMA
IO-link interface for service and process data
Fuction indicator LED yellow:
constantly on - switch output active
constantly off - switch output inactive
Control elements Teach-In key
Electrical specifications
Operating voltage 10 ... 30 V DC
terface type IO-Link ( via C/Q = BK )
IO-Link Revision 1.1
Product standard EN 60947-5-2:2007+A1:2012
Miniature design with versatile mounting options
Multi Pixel Technology (MPT) - flexibility and adaptability
Reduction of device variety - several switch points within one sensor
Reliable detection of all surfaces, independent of color and structure
Low sensitivity to target color
Switching diffuse mode sensor with measurement core t
echnology, 150 mm detection range, red light, IO-Link, 2 x push-pull output, 2 m fixed cable
General specifications
Detection range 5 ... 150 mm
021-39526589
網址:2i4bx9r.cn
地 址:上海市嘉定區嘉涌路99弄